SKU_CM-26dG

CM-26dG Portable Spectrophotometer

  • CM-26dG Portable Spectrophotometer

    The CM-26dG spectrophotometer is a highly advanced and portable device that combines color and gloss measurement capabilities in one instrument. Its horizontal alignment allows it to fit into narrow spaces, making it suitable for precise measurement of smooth or textured samples. The ergonomic design ensures easy operation for both right and left-handed users, while optional Bluetooth™ and a high-resolution TFT color display enhance its usability in the field.

    The spectrophotometer offers remarkable accuracy and inter-instrument agreement, usually found only in laboratory-grade equipment. This level of precision enables superior color communication throughout the supply chain. The chromaticity value inter-instrument agreement has been significantly improved by approximately 40% compared to previous models.

    Accuracy
    Ease of Use

    The CM-26dG Spectrophotometer features a user-friendly interface that makes it easy to operate, even for novice users. It has a large LCD display that provides clear and easy-to-read measurement data, and it can be used with both the included software or third-party software.

     

    The CM-26dG Portable Spectrophotometer comes with SpectraMagic NX colour measurement software package  that can be used to interface with Konica Minolta instruments and provide extended reporting and analysis of colour and colour difference.

    Measurement Capability:

    Because of the way supply chains are constantly being built and modified, data needs to be shared amongst increasingly more sites. This has made high repeatability and high inter-instrument agreement prerequisites for portable spectrophotometers. The CM-26dG and CM-26d realize the highest level of inter-instrument agreement amongst currently available portable spectrophotometers, at ΔE*ab 0.12 (BCRA average amongst 12 colors). And when measuring gloss, inter-instrument agreement of the CM-26dG is within ±0.2 GU (0-10 GU) or ±0.5 GU (10-100 GU). Moreover, repeatability is half that of predecessor models, at ıΔE*ab 0.02. The contribution to digital color data management that this level of performance offers will help manufacturers enhance quality management between their factories and suppliers

    TouchScreen
    Dimensions - RPimaging, INC - Dimensions
    Design and Build Quality

    Designed to work in hard-to-reach places, the CM -26dG Series spectrophotometers allow users to take measurements where previous models could not. The nose is angled downward and rounded at the corners to get into cramped spots like dashboards at a point near the windshield. Moreover, the plastic target mask lessens the risks of scratching the sample. And there is a trigger button on both sides so that measurements can be taken stress-free in any sort of situation, no matter which hand you use.

    Connectivity

    The CM-26dG Spectrophotometer features built-in USB and Ethernet connectivity that allows users to transfer measurement data directly to their computer or network. It also supports wireless connectivity options, including Wi-Fi and Bluetooth, for added convenience

    CM-26dG
    CT1
    CM-CT1 Configuration Tool

    The CM-26d comes with the CM-CT1 Configuration Tool software, which allows users to create and write instrument settings and compile them into a file to share within its supply chain to ensure consistent instrument settings.

     

    The New Color Data Software SpectraMagic NX2 - Pro version / Lite version

     

    SpectraMagic™ NX2 is an improved software solution for digital color data, developed to allow users a streamlined system for operating Konica Minolta color measuring instruments, capturing, comparing and communicating color data within the business and between supply chain partners. SpectraMagic™ NX2 offers users a far smoother experience than its predecessor SpectraMagic™ NX.

     

    Spectramagic_NX2 - RPimaging, INC - Spectramagic_NX2

     

    Optimize Color Control with SpectraMagic NX2

    SpectraMagic NX2 by Konica Minolta is a cutting-edge software designed to meet the demanding needs of color quality control across various industrial sectors. Whether you are in the automotive, paint, plastics, cosmetics, or food industries, this software offers a complete and intuitive solution for precise color analysis.


    Minimum Computing Requirements

    OS: Windows® 10 Pro 64 bit Version 1903 or higher/
    Windows® 11 Pro
    CPU: Intel® Core i5 2.7 GHz or higher processor (recommended)
    Memory: 2 GB or more (4 GB or more recommended)
    Storage: 10 GB or more
    USB port: Required for dongle version
    Connection to external network: Required for activation

     

    Main features

    Observer 2°, 10°
    Color system
    color space
    Pro, Lite L*a*b*, L*C*h, Lab99, LCh99, Lab99o, LCh99o, Hunter Lab, and their color differences; Munsell (C, D65)
    Pro Only XYZ, Yxy, u'v', u*v*, and their color differences
    Index Pro, Lite MI; GU and difference (CM-25cG, CM-26dG, CM-36dG/CM-36dGV); Opacity (ISO 2471, TAPPI T425 89% white plate)*2
    CM-5/CR-5 only: Gardner, Iodine Color Number, Hazen/APHA, European Pharmacopeia, US Parmacopeia
    Pro Only WI (CIE1982, ASTM E313-73, Hunter, ASTM E313-98, BERGER, TAUBE, STENSBY, Ganz); YI (ASTM D1925-70, ASTM E313-73, ASTM E313-98, DIN 6167); B (ASTM E313-73); Tint (CIE 1982, ASTM E313-98, Ganz); Standard Depth (ISO 105.A06); Brightness (TAPPI T452, ISO 2470); Density (Status A, Status T); Dominant Wavelength; Excitation Purity; 555; RxRyRz; Grey Scale/Grey Scale Rating (ISO 105.A05); K/S Strength (Apparent, (ΔE*ab, ΔL*, ΔC*, ΔH*, Δa*, Δb*, Maximum absorption, Total wavelength, User wavelength); Strength; Pseudo strength; Staining degree/degree grade (ISO 105.A04E); NC#; NC#Grade; Ns; Ns Grade; Signal color index; 8° gloss/8° gloss difference (for simultaneous SCI/SCE measurements only); FF/FF difference (CM-M6); User equation; Haze (ASTM D1003-97)*2; Blackness(My) (ISO18314-3/DIN55979), Jetness(Mc) (ISO18314-3), and Undertone(dM) (ISO18314-3)
    Color
    Difference
    Formula
    Pro, Lite ΔE*ab (CIE1976); ΔE00 (CIE DE2000) and each component of lightness; saturation and hue; ΔE99(DIN99), ΔE(Hunter); ΔE*94 (CIE 1994) and each component of lightness; saturation and hue; CMC and each component of lightness; saturation and hue; ΔE99o and each component of lightness; saturation and hue
    Pro Only ΔE*94 (Special) and each component of lightness; saturation and hue; ΔEc(degree)(DIN 6175); ΔEp(degree)(DIN 6175; FMC-2; NBS 100; NBS 200; Audi2000
    Illuminant Pro, Lite A, C, D50, D65, F2, F11
    Pro Only D55, D75, F6, F7, F8, F10, F12, U50, ID50, ID65, LED-B1, LED-B2, LED-B3, LED-B4, LED-B5, LED-BH1, LED-RGB1, LED-V1, LED-V2, User illuminant (100 maximum)
    Graphic
    and
    canvas
    objects
    Pro, Lite Spectral reflectance (transmittance) and its difference; L*a*b* absolute color distribution; Hunter Lab absolute color distribution; ΔL*a*b* color difference distribution; Hunter ΔLab; xy chromaticity diagram; Trend graph; Histogram; Multichannel graph; 2D user-specified axis graph Text labels, Numerical labels, Images, Data lists, Statistics, Pseudo-color patches
    Pro Only K/S and its difference; Absorbance and its difference
    Features Pro, Lite Viewfinder (CM-36d series); Manual averaging measurement; Trigger measurement (excluding CM3700A, CM-3600A and CM-3610A) Categorize by tags; Attaching images/comments; Evaluation results·pass/fail judgment; Import/export; Stored data reading/target data writing (excluding CM-3700A, CM-3600A, CM-3610A and CM-36d series) Shortcut key settings; Display template creation / output / application; Report printing; Printing to serial printer; Sound (on measurement, pass judgment, fail judgment)
    Pro Only User calibration, UV adjustment Interval measurement User management/operation restrictions Data search under specified conditions; User illuminant source registration (manual input, from file, from CL-500); Automatic selection of standards; Auto tolerance; Classification by user defined information QC template creation/editing/output; Macro function; External software startup; Job settings (CM-26d/ CM-25d/CM-26dG, CM-25cG)
    Number of files and data Number of files that can be opened simultaneously: 10 Number of data that can be stored in a file: 10,000 (total of target data and measurement data)
    Supported file formats NX2 (.mesx2, .mtpx2), NX (.mtp, .mes, .mea; reading only); Other (.csv (output only), .cxf); SpectraMagic DX files (.mesx) need to be converted to .mes with a conversion tool NX2 QC template *.qctp (PRO: create/edit/save, LITE: read only)
    Display languages Japanese, English, German, French, Spanish, Italian, Portuguese, Chinese (Simplified and Traditional), Turkish, Russian, Polish, Korean