| Light source |
Pulsed xenon lamp ×2 |
Pulsed xenon lamp ×2 |
Pulsed xenon lamp ×1 |
Pulsed xenon lamp ×1 |
| Detector |
Dual 40-element silicon photodiode arrays |
Dual 40-element silicon photodiode arrays |
Dual 32-element silicon photodiode arrays |
Dual 32-element silicon photodiode arrays |
| Measurement wavelength range |
360 to 740 nm |
360 to 740 nm |
400 to 700 nm |
400 to 700 nm |
| Measurement area |
MAV: Ø8 mm, SAV: Ø3 mm |
MAV: Ø8 mm, SAV: Ø3 mm |
MAV : Ø8 mm |
MAV : Ø8 mm |
| Illumination area |
12 × 12.5 mm (circle + ellipse) |
MAV : Ø12 mm SAV : Ø6 mm |
MAV : Ø12 mm |
MAV : Ø12 mm |
| Repeatability |
Standard deviation within ΔE*ab 0.02 |
Standard deviation within ΔE*ab 0.02 |
Standard deviation within ΔE*ab 0.04 |
Standard deviation within ΔE*ab 0.08 |
| (When a white calibration plate is measured 30 times at 5-second intervals after white calibration) |
| Inter-instrument agreement |
Within ΔE*ab 0.12 |
Within ΔE*ab 0.12 |
Within ΔE*ab 0.20 |
Within ΔE*ab 0.40 |
| (Based on average for 12 BCRA Series II color tiles; MAV SCI; compared to values measured with a master body under KONICA MINOLTA standard measurement conditions) |
| UV |
100% / 0% selectable |
100% / 0% selectable |
0% only |
0% only; 400nm UV cutoff filter |
| Illuminant |
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65, User-defined illuminant* 1 (Simultaneous evaluation with two light sources possible) |
| Indexes |
MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), Strength, Opacity, Grey scale, User index *1 |
MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), Strength, Opacity, Grey scale, 8° gloss value, User index * |
MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), Strength, Opacity, Grey scale, 8° gloss value, User index * |
MI, W (I ASTM E313-73), YI (ASTM D1925), Opacity, |
| Color difference equations |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) |
| Applicable standards |
DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15 |
DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15 |
DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15 |
ISO 7724/1, CIE No.15, DIN 5033 Teil 7, JIS Z 8722 Condition “c” |
| Measurement time |
Approx. 1 sec. (Measurement mode: SCI + Gloss or SCE + Gloss) |
Approx. 0.7 s (Measurement mode: SCI or SCE) |
Approx. 0.7 s (Measurement mode: SCI or SCE) |
Approx. 0.7 s (Measurement mode: SCI or SCE) |
| (From pressing trigger button to measurement completion) |
| Minimum measurement interval |
Approx. 2 s (Measurement mode: SCI or SCE) |
Approx. 1.5 s (Measurement mode: SCI or SCE) |
Approx. 1.5 s (Measurement mode: SCI or SCE) |
Approx. 1.5 s (Measurement mode: SCI or SCE) |
| Data memory |
1,000 target data + 5,100 sample data |
1,000 target data + 5,100 sample data |
1,000 target data + 5,100 sample data |
1,000 target data + 1,700 sample data |
| Battery performance |
Measurement mode: SCI + Gloss or SCE + Gloss |
Measurement mode: SCI or SCE |
Measurement mode: SCI or SCE |
Measurement mode: SCI or SCE |
| Approx. 3,000 measurements (approx. 1,000 measurements when using Bluetooth) when measurements are taken at 10-second intervals at 23°C with the dedicated lithium battery |
| Weight |
Approx. 660 g |
Approx. 630 g |
Approx. 620 g |
Approx. 620 g |
| Illumination/viewing system |
di: 8°, de: 8° (diffuse illumination: 8° viewing) SCI (specular component included) / SCE (specular component excluded) switchable |
| Integrating sphere |
Ø54 mm |
| Light source |
Pulsed xenon lamp ×2 |
Pulsed xenon lamp ×2 |
Pulsed xenon lamp ×1 |
Pulsed xenon lamp ×1 |
| Detector |
Dual 40-element silicon photodiode arrays |
Dual 40-element silicon photodiode arrays |
Dual 32-element silicon photodiode arrays |
Dual 32-element silicon photodiode arrays |
| Spectral separation device |
Planar diffraction gratin |
| Measurement wavelength range |
360 to 740 nm |
360 to 740 nm |
400 to 700 nm |
400 to 700 nm |
| Measurement wavelength pitch |
10nm |
| Half bandwidth |
Approx. 10 nm |
| Illumination/viewing system |
0 to 175%; Display resolution: 0.01 |
| Illumination area |
12 × 12.5 mm (circle + ellipse) |
MAV : Ø12 mm SAV : Ø6 mm |
MAV : Ø12 mm |
MAV : Ø12 mm |
| Measurement area |
MAV: Ø8 mm, SAV: Ø3 mm |
MAV: Ø8 mm, SAV: Ø3 mm |
MAV : Ø8 mm |
MAV : Ø8 mm |
| Repeatability |
Standard deviation within ΔE*ab 0.02 |
Standard deviation within ΔE*ab 0.02 |
Standard deviation within ΔE*ab 0.04 |
Standard deviation within ΔE*ab 0.08 |
| (When a white calibration plate is measured 30 times at 5-second intervals after white calibration) |
| Inter-instrument agreement |
Within ΔE*ab 0.12 |
Within ΔE*ab 0.12 |
Within ΔE*ab 0.20 |
Within ΔE*ab 0.40 |
| (Based on average for 12 BCRA Series II color tiles; MAV SCI; compared to values measured with a master body under KONICA MINOLTA standard measurement conditions) |
| UV |
100% / 0% selectable |
100% / 0% selectable |
0% only |
0% only; 400nm UV cutoff filter |
| Observer |
2° observer angle, 10° observer angle |
| Illuminant |
A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65, User-defined illuminant* 1 (Simultaneous evaluation with two light sources possible) |
| Display items |
Colorimetric values/graph, color difference values/graph, spectral graph, pass/fail judgment, pseudocolor |
| Colorimetric values |
L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, and color difference in these spaces; Munsell (C) |
| Indexes |
MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), Strength, Opacity, Grey scale, User index *1 |
MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), Strength, Opacity, Grey scale, 8° gloss value, User index * |
MI, WI (ASTM E313-73), YI (ASTM E313-73, ASTM D1925), ISO brightness (ISO 2470), WI/Tint (CIE), Strength, Opacity, Grey scale, 8° gloss value, User index * |
MI, W (I ASTM E313-73), YI (ASTM D1925), Opacity, |
| Color difference equations |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) / Hunter ΔE / DIN99o |
ΔE*ab (CIE1976) / ΔE94 (CIE1994) / ΔE00 (CIE2000) / CMC (l:c) |
| Applicable standards |
DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15 |
DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15 |
DIN 5033 Teil 7, JIS Z 8722 Condition “c”, ISO 7724/1, CIE No.15 |
ISO 7724/1, CIE No.15, DIN 5033 Teil 7, JIS Z 8722 Condition “c” |
| Measurement time |
Approx. 1 sec. (Measurement mode: SCI + Gloss or SCE + Gloss) |
Approx. 0.7 s (Measurement mode: SCI or SCE) |
Approx. 0.7 s (Measurement mode: SCI or SCE) |
Approx. 0.7 s (Measurement mode: SCI or SCE) |
| (From pressing trigger button to measurement completion) |
| Minimum measurement interval |
Approx. 2 s (Measurement mode: SCI or SCE) |
Approx. 1.5 s (Measurement mode: SCI or SCE) |
Approx. 1.5 s (Measurement mode: SCI or SCE) |
Approx. 1.5 s (Measurement mode: SCI or SCE) |
| Data memory |
1,000 target data + 5,100 sample data |
1,000 target data + 5,100 sample data |
1,000 target data + 5,100 sample data |
1,000 target data + 1,700 sample data |
| Battery performance |
Measurement mode: SCI + Gloss or SCE + Gloss |
Measurement mode: SCI or SCE |
Measurement mode: SCI or SCE |
Measurement mode: SCI or SCE |
| Approx. 3,000 measurements (approx. 1,000 measurements when using Bluetooth) when measurements are taken at 10-second intervals at 23°C with the dedicated lithium battery |
| Viewfinder function |
Available (with white LED illumination) |
| Display |
2.7" color TFT-LCD with reversible portrait viewing mode |
| Display language |
English, Japanese , German, French, Italian, Spanish, Simplified Chinese, Portuguese, Russian, Turkish, Polish |
| Interface |
USB 2.0; Bluetooth (SPP-compatible. Optional Bluetooth module required) |
| Power |
Dedicated lithium-ion battery (removable), USB bus power (with lithium-ion battery installed), Dedicated AC adapter (with lithium-ion battery installed) |
| Charging time |
Approx. 6h |
| Operating temperature/humidity range |
Temperature: 5 to 40°C, Relative humidity: 80% or less (at 35°C) with no condensation |
| Storage temperature/humidity range |
Temperature: 0 to 45°C, Relative humidity: 80% or less (at 35°C) with no condensation |
| Size |
Approx. 81 (W) × 93 (H) × 229 (D) mm |
| Weight |
Approx. 660 g |
Approx. 630 g |
Approx. 620 g |
Approx. 620 g |