Search our catalog

We also offer custom consulting and training services for commercial, digital, flexo, web, and grand format printing markets.

Lighting

Monitors

Spectrophotometers

Densitometers

Color Communication

All the hardware you need to ensure the quality of your color

All the software you need to ensure the quality of your color

BW17

Substrate Backer XL

  • Substrate Backer XL

    Double side black and white measurement backing according to ISO:13655
    Size: 279x 449 mm (effective 279 x 430mm) (Approx 11" x 17")


    Specification:

     

    White Backing Area
    According to ISO:13655, white backing should have a diffuse-reflecting surface.

    Typical ChromaChecker QC batch production measurement:

    • Opacity 100% (99,3% single page) [expected value >99%}]
    • FLuorescence = 0,0 [expected 0,0]
    • L*= 94,6 [requirement: L* shall not exceed 97], a*=-0,94 b*= 1,34
    • C*=1,64 [requirement - shall not be larger then 3.00], h*=125,1
    • Reflectance for given wavelength shall bein given by ISO13655 range 380-730nm:

    0,1190 0,2258 0,4528
    0,6727 0,7738 0,8069 0,8224 0,8345 0,8453 0,8530 0,8582 0,8613 0,8619
    0,8611 0,8603 0,8570 0,8538 0,8499 0,8444 0,8461 0,8470 0,8474 0,8467
    0,8472 0,8469 0,8481 0,8515 0,8555 0,8584 0,8627 0,8668 0,8688 0,8733
    0,8765 0,8767



    Black Backing area
    According to ISO:5-4 black banking should have a diffuse-reflecting surface.

    Typical ChromaChecker QC batch production measurement:
    Average Density = 1,44 [have to be between 1.30 – 1.70]
    Density Range = 3,9 [expected value shall be less than 5]